Logo
×

Category


For More Information about the product contact us, order quote request or call 800.565.5278

DE Series Relay/Control

Application

precise digital control for consistent plating and etch rates in most aqueous processes.

Materials

N/A

Performance

30 amps switching capabilities

Specifications

See product bulletin for details

Features

- Large (.56” high), easy to read LED display. Provides precise control for consistent plating and etch rates in most aqueous processes.

- NEMA 1, IP21, flame retardant and gasketed plastic enclosure with stainless steel hardware

- 20°F(-7°C) to 140°F(60°C) ambient temperature range

- Single phase only

- Fluoropolymer (FEP) covered 10-foot (3m), 1000- ohm platinum RTD sensor included standard with the control. Provides extended service in corrosive liquids and can be lengthened with ordinary copper wire

- 30 amp switching capacities for 120 - 240 volts

- ±.25% full span, single digit accuracy

- Pre-wired outlets for plug-in heaters (16 amp max load)


30 amp, Single Set-Point, Precise Control.

Provides precise digital control for consistent plating and etch rates in most aqueous processes. Large (.56” high), easy to read LED display. Vapor tight, IP21, front panel protection. ±.25% full span, single digit accuracy. 30 amps switching capabilities. 120-240 volts. Adjustable temperature range from -40°F (-40°C) to 999°F (538°C).

Options: Scalable voltage and current inputs. Three wire 100-ohm RTD sensors. Special sensors required for temperatures above 500°F(260°C). 25-foot (7.6m) and 50-foot (15.2m) sensors. P2, P3 or P8 thermal protection systems. Integrated liquid level control components. Front panel mounted digital timers.  Ground fault protection of equipment (GFPE) circuitry. Combination controls available for three phase service and larger heater loads. NEMA 4/4X enclosure (with internal heater for outdoor use.

Safety: Pre-wired P1 terminal blocks. Non-volatile memory. Programmable high alarm shutdown. Sensor short and break protection. Security code restricted menu. Programmable high set point limit.